2 data block 1, Data block 1, Interface plc <˘> nc operating system – Lenze ETC Motion Control User Manual
Page 245
![background image](/manuals/566331/245/background.png)
Interface PLC <˘> NC operating system
Definitions
Data block 1
5.1
5.1.2
l
245
EDSTCXN EN 2.0
Data word
Name
Direction
Type of signal
136
Error number
NC
® PLC
static
This is where the actual error number is reported. An error number is always
assigned to the corresponding error module. The error can only be clearly de-
termined by means of the error number and error module.
Data word
Name
Direction
Type of signal
137
Current submenu
NC
® PLC
static
reserved
Data word
Name
Direction
Type of signal
148.00−255.15
Text output G253
NC
® PLC
static
The texts that are output with the G function G253 (without parameter E)
are shown from DW148 onwards for the PLC.
5.1.2
Data block 1
In data block 1 the standard signals are exchanged. Standard signals are all
signals and messages recorded in the respective specifications, which reflect
the state of the PLC and the NC and affect the operation of the NC or the PLC.
They are also signals/messages that do not exist in the general specifica-
tions but are part of the standard scope of the ETC.
In the following, you can find an overview of the assignment of the data
block. This is followed by individual descriptions of signals and messages.
Data word
Name
Direction
000.00
000.01
000.02
000.03
db1_sps2nc_notaus_bit
db1_sps2nc_vorschubfreigabe_bit
db1_sps2nc_soforthalt_bit
db1_sps2nc_einzelfunktionsperre_bit
PLC
® NC
PLC
® NC
PLC
® NC
PLC
® NC
001.00 – 001.15
002.00 – 002.15
db1_sps2nc_vorschubfreigabe_w
db1_sps2nc_position_halt_w
PLC
® NC
PLC
® NC
003.00 – 003.15
004.00 – 004.15
db1_sps2nc_verfahrtastenfreigabe_plus_w
db1_sps2nc_verfahrtastenfreigabe_minus_w
SP
® NC
PLC
® NC
005.00 – 005.15
db1_sps2nc_reglerfreigabe_w
PLC
® NC
007.00
db1_sps2nc_einlesefreigabe_bit
PLC
® NC
009.00 – 009.07
db1_sps2nc_programmstart_b
PLC
® NC
009.08 – 009.11
db1_sps2nc_use_spsoverride_b
PLC
® NC
012.00
db1_sps2nc_programmstop_b
PLC
® NC
012.08
db1_sps2nc_unterbrechen_bit
PLC
® NC
013.00 – 013.07
db1_sps2nc_einzel_folgesatz_bit
PLC
® NC
013.08 – 013.15
db1_sps2nc_satzausblenden_bit
PLC
® NC
014.00
db1_sps2nc_rueckzug_bit
PLC
® NC
016.00 – 017.15
db1_sps2nc_tastensignale_aw
PLC
® NC
018.00 – 021.15
db1_sps2nc_qbit_signale_aw
PLC
® NC
031.00 – 031.15
DB1_sps2nc_freigaben_mmi_w
PLC
® NC
032.00
db1_sps2nc_mfkt_quitt_bit
PLC
® NC
Assignment