Interface PLC <˘> NC operating system
Definitions
Data block 1
5.1
5.1.2
l
246
EDSTCXN EN 2.0
Direction
Name
Data word
033.00
db1_sps2nc_hfkt_quitt_bit
PLC
® NC
035.00
db1_sps2nc_extsync_enable_bit
PLC
® NC
035.08
db1_sps2nc_programmhalt_aktiv_bit
PLC
® NC
036.00 – 037.15
038.00 – 039.15
db1_sps2nc_qin_mask_aw
db1_sps2nc_qout_mask_aw
PLC
® NC
PLC
® NC
042.00 – 043.15
044.00 – 045.15
db1_sps2nc_qin_offset_ab
db1_sps2nc_qout_offset_ab
PLC
® NC
PLC
® NC
080.00 – 080.15
081.00 – 081.15
082.00 – 082.15
083.00 – 083.15
db1_sps2nc_spsoverride_allg_w
db1_sps2nc_spsoverride_spindel_w
db1_sps2nc_spsoverride_ozillation_w
db1_sps2nc_spsoverride_sps_w
PLC
® NC
PLC
® NC
PLC
® NC
PLC
® NC
084.00 – 091.15
db1_sps2nc_verfahr_ab
PLC
® NC
128.00
128.01
db1_nc2sps_betriebsbereit_1_bit
db1_nc2sps_betriebsbereit_2_bit
PLC
¬ NC
PLC
¬ NC
129.00 – 129.15
db1_nc2sps_referenzpunkt_w
PLC
¬ NC
130.00 – 131.15
db1_nc2sps_referenzfahrt_laeuft_w
PLC
¬ NC
131.00 – 131.15
db1_nc2sps_betriebsart_w
PLC
¬ NC
132.00
132.02
132.03
132.04
db1_nc2sps_nc_programm_laeuft_bit
db1_nc2sps_satzvorlauf_aktiv_bit
db1_nc2sps_einzelsatz_laeuft_bit
db1_nc2sps_unterbrechen_aktiv_bit
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
132.08
db1_nc2sps_alle_achsen_stehen_bit
PLC
¬ NC
133.00 – 133.07
db1_nc2sps_wahlweise_halt_b
PLC
¬ NC
133.08 – 133.15
db1_nc2sps_programmstartzaehler_b
PLC
¬ NC
134.00 – 134.15
db1_nc2sps_achse_faehrt_w
PLC
¬ NC
135.00 – 135.15
db1_nc2sps_modal_am_ziel_w
PLC
¬ NC
137.00 – 137.07
db1_nc2sps_programmstart_b
PLC
¬ NC
137.08 – 137.15
db1_nc2sps_einzel_folgesatz_bit
PLC
¬ NC
138.00 – 138.15
139.00 – 139.15
db1_nc2sps_canmodul_vorhanden_w
db1_nc2sps_can_status_w
PLC
¬ NC
PLC
¬ NC
142.00
db1_nc2sps_programmstop_b
PLC
¬ NC
144.00
db1_nc2sps_vorschub_halt_b
PLC
¬ NC
150.00
151.00 – 151.15
db1_nc2sps_mfkt_strobe_bit
db1_nc2sps_mfkt_w
PLC
¬ NC
PLC
¬ NC
159.00
160.00 – 160.15
db1_nc2sps_hfkt_strobe_bit
db1_nc2sps_hfkt_w
PLC
¬ NC
PLC
¬ NC
177.00 – 177.15
db1_nc2sps_refpunkt_angefahren_w
PLC
¬ NC
178.00 – 178.15
179.00 – 179.15
180.00 – 180.15
181.00 – 181.15
db1_nc2sps_endschalter_plus_w
db1_nc2sps_endschalter_minus_w
db1_nc2sps_referenznocken_w
db1_nc2sps_reserveeingang_w
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
182.00 – 182.15
183.00 – 183.15
184.00 – 184.15
185.00 – 185.15
db1_nc2sps_slave_endschalter_plus_w
db1_nc2sps_slave_endschalter_minus_w
db1_nc2sps_slave_referenznocken_w
db1_nc2sps_slave_reserveeingang_w
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
192.00 – 199.15
db1_nc2sps_copmodul_vorhanden_aw
PLC
¬ NC
200.00 – 200.15
201.00 – 201.15
202.00 – 202.15
203.00 – 203.15
db1_nc2sps_spsoverride_allg_w
db1_nc2sps_spsoverride_spindel_w
db1_nc2sps_spsoverride_ozillation_w
db1_nc2sps_spsoverride_sps_w
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
PLC
¬ NC
204.00 – 211.15
db1_nc2sps_verfahr_ab
PLC
¬ HMI
212.00 – 219.15
db1_nc2sps_mmi_tasten_aw
PLC
¬ HMI
All of the areas that are not listed explicitly are reserved.