Tpc learning infrared receiver, To enter learn mode, To learn an ir code – ETC Unison Mosaic Designer v1.11.0 User Manual
Page 240: To test an ir slot, To erase an ir code, To exit learn mode
Unison Mosaic Designer User Manual
TPC learning infrared receiver
The TPC may be taught to recognise up to 16 different infrared (IR) codes from a standard IR remote control.
When a key on the remote control is pressed during normal operation, the TPC will react as though one of its user
interface controls has been touched.
The TPC does not have to be part of a networked system to learn IR codes, all that is required is PoE power and
the donor remote control:
To enter Learn Mode:
1. Enter by pressing the CFG (config) button. This is located underneath the magnetic overlay at the top left of the
display, underneath the Reset button.
l
The screen will display the IR configuration interface.
To learn an IR code:
1. Press the Set button alongside the code to be learnt.
l
A progress indication will appear on the left of the row.
2. Within ten seconds, point the IR remote at the TPC and press the desired key.
l
The progress indication will be replaced with a tick icon when the code has been learnt.
To test an IR slot
1. Point the IR remote at the TPC and press a key.
l
If the IR code received is associated with an IR slot, the slot will be highlighted.
2. Release the key on the IR remote.
l
The IR slot will no longer be highlighted.
To erase an IR code:
1. Press the Clear button alongside the code to be erased.
l
The tick icon next to the code will disappear.
To exit Learn Mode:
1. Press the CFG (config) button.
l
The screen will display the user interface for the loaded presentation, or indicate that no user interface is
present on the memory card.