Network - controller interfaces, Configure tpc-rio (tpc only), Inputs (msc 1, 2 & 4 and tpc with tpc-rio only) – ETC Unison Mosaic Designer v1.11.0 User Manual
Page 154: Interfaces, Controller interfaces, Controller inter, Faces

Unison Mosaic Designer User Manual
Network - Controller Interfaces
Choose the Interfaces tab to configure the input/output interfaces for a Controller, including any Expansion Mod-
ules:
IMPORTANT: Changes made to a Controller's interfaces will only take effect after an
.
Configure TPC-RIO (TPC only)
Check the "Configure TPC-RIO" box if you want to see TPC-RIO interfacing options for a TPC.
Inputs (MSC 1, 2 & 4 and TPC with TPC-RIO only)
Check the "Check State At Startup" box if you want the inputs to be read and acted upon in
at startup.
The inputs of the revised MSC and TPC-RIO can be individually configured as either Contact Closure, Digital or
Analog with the latter two modes allowing for the threshold or range to be selected. The maximum voltage range
is 0-24V and the smallest measurable change is 0.25V.
- 154 -