ETC Unison Mosaic Designer v1.11.0 User Manual
Page 180
Unison Mosaic Designer User Manual
Trigger '?' requires a valid RS485 port number
Reconfigure the trigger with the correct port number
(1, unless using two RS485 modules on one Con-
troller, in which case 2 may be valid)
Trigger '?' requires the serial port on controller '?' to be set
to RS485
Reconfigure the serial port of the Controller to use
the correct mode, see
Trigger '?' requires a valid DMX In port number
Reconfigure the trigger with the correct port number
(1, unless using two DMX-In modules on one Con-
troller, in which case 2 may be valid)
Trigger '?' is set to match with controller '?', which requires
the DMX In port to be set to 1
Controller only supports one DMX input port, so set
the trigger DMX port to 1
Trigger '?' requires the serial port on controller '?' to be set
to DMX
Reconfigure the serial port of the Controller to use
the correct mode, see
Trigger '?' is set to match with controller '?', but that con-
troller has disabled DMX In
Reconfigure the DMX input for the Controller, see
.
Trigger '?' uses the MIDI In port, but controller '?' doesn't
have a MIDI In port
Reconfigure the trigger to use a Controller with a
MIDI In port
Trigger '?' requires a valid Audio module number
Reconfigure the trigger with the correct Module num-
ber
Trigger '?' requires a valid DALI Slave module number
Reconfigure the trigger with the correct Module num-
ber
Condition '?' will not be tested on controller '?' because the
controller doesn't support digital inputs
Reconfigure the trigger with a controller that does
support digital inputs
Condition '?' requires input '?' on controller '?' to be con-
figured as a digital input or contact closure
The Controller's input has been configured incor-
rectly, see
Condition '?' will not be tested on controller '?' because the
controller doesn't support analog inputs
Choose a Controller that does have analog inputs
Condition '?' on trigger '?' requires a valid DMX In port num-
ber
Reconfigure the trigger with the correct port number
Action '?' is set to run on controller '?', but no controller has
that number
Reconfigure the trigger with the correct Controller
number
Action '?' will not be run because controller '?' isn't a TPC
Reconfigure the trigger with the correct Controller
number
Action '?' requires a serial port, but controller '?' doesn't
have a serial port
Choose a Controller that does have a serial port
Action '?' is set to use controller '?', which requires the
serial port to be set to 1
Controller only supports one serial port, so set the
action serial port to 1
Action '?' requires the serial port on controller '?' to be set
to RS232
Reconfigure the serial port of the Controller to use
the correct mode, see
- 180 -