Dmx proxy (msc 1 only), Etcnet2, Kinet power supplies – ETC Unison Mosaic Designer v1.11.0 User Manual
Page 152: Dvi (msc x only)
Unison Mosaic Designer User Manual
DMX Proxy (MSC 1 only)
If a Designer project has a TPC and an MSC 1, the TPC can output local DMX via the MSC's second DMX port.
With the MSC 1 selected, choose the TPC from the drop down list.
ETCNet2
Configure as required:
l
Source number - ETCNet2 multicast address references, from 1 to 26, default is 1
l
Source priority - ETCNet2 output arbitration references, from 1 to 20, typically 10
KiNet power supplies
These configuration settings are used to manage the KiNet power supplies if required. Press the Add button to
add a KiNet power supply using the Select a power supply dialog:
Select the appropriate power supply from the list and press Ok (or Cancel to abort). Add more power supplies if
required.
Once you have added your KiNet power supplies use the power supply pull-down and the fields below to con-
figure each in turn:
l
Address - The power supply's IP address
l
Number - A unique user number for the power supply
l
Name - A name for the power supply
l
Comment - An optional field for additional information (location, purpose etc)
Use the Remove button to delete the selected power supply, all patch data will be lost.
DVI (MSC X only)
To output data using the DVI port you must first create a
that matches the LED controller's pixel map.
Once this has been done, use the Pixel Matrix pull-down on the protocol tab to select which matrix will be output
via the DVI port. Any programming for the fixtures in the pixel matrix will now output on the DVI port, not just pro-
gramming applied directly to the pixel matrix.
The MSC X's DVI port is set to a fixed 1024x768@60Hz resolution which is compatible with most LED con-
trollers. The LED controller (or monitor) MUST be connected when the MSC X boots or resets for the port to
become active.