Issues

Action '?' uses the RS485 serial port, but controller '?'
doesn't have an RS485 serial port

Reconfigure the action to use a Controller that does
have an RS285 serial port

Action '?' on trigger '?' requires a valid RS485 port number Reconfigure the trigger with the correct port number

Action '?' requires the serial port on controller '?' to be set
to RS485

Reconfigure the serial port of the Controller to use
the correct mode, see

Controller Interfaces

Action '?' uses the MIDI Out port, but controller '?' doesn't
have a MIDI Out port

Reconfigure the trigger to use a Controller with a
MIDI Out port

Action '?' is using the same variable to select the BPS
number and the button number

Check the variables assigned to these fields in the
action properties

Trigger '?' requires input '?' on '?' to be configured as a
digital input or contact closure

The RIO's input has been configured incorrectly, see

Remote Devices

Trigger '?' requires '?' to be configured as an Audio input
device

The RIO has been configured incorrectly, see

Remote Devices

Trigger '?' uses frequency band '?' on '?' but that device
doesn't provide that band

Select a band that is available for that device, or
reconfigure the RIO, see

Remote Devices

Condition '?' requires input '?' on '?' to be configured as a
digital input or contact closure

The RIO's input has been configured incorrectly, see

Remote Devices

Condition '?' expects all inputs on '?' to be configured as
either digital inputs or contact closures

The RIO's input has been configured incorrectly, see

Remote Devices

Condition '?' requires input '?' on '?' to be configured as an
analog input

The RIO's input has been configured incorrectly, see

Remote Devices

Ethernet Bus '?' uses port '?'. This clashes with the
internal web server and will prevent correct operation of
controller '?'

Reconfigure the Ethernet bus to use a different port

Ethernet Bus '?' uses port '?'. This clashes with file trans-
fer and will prevent correct operation of controller '?'

Reconfigure the Ethernet bus to use a different port

Controller '?' is outputting KiNet so ensure the DHCP
server on protocol network interface is serving an IP
address on the same network as the patched power sup-
plies

Configure the DHCP server to use a 10.xxx.xxx.xxx
IP address

Controller '?' is outputting KiNET so ensure that the pro-
tocol network interface IP address is on the same network
as the patched power supplies

Reconfigure the Protocol port to use a
10.xxx.xxx.xxx IP address

Multiple KiNet power supplies have the IP address '?'

Reconfigure power supplies to use unique IP
addresses

Controller '?' is outputting KiNet so ensure that the con-
troller IP address is on the same network as the patched
power supplies

Reconfigure the Controller to use a 10.xxx.xxx.xxx
IP address