Issues
Action '?' uses the RS485 serial port, but controller '?'
doesn't have an RS485 serial port
Reconfigure the action to use a Controller that does
have an RS285 serial port
Action '?' on trigger '?' requires a valid RS485 port number Reconfigure the trigger with the correct port number
Action '?' requires the serial port on controller '?' to be set
to RS485
Reconfigure the serial port of the Controller to use
the correct mode, see
Action '?' uses the MIDI Out port, but controller '?' doesn't
have a MIDI Out port
Reconfigure the trigger to use a Controller with a
MIDI Out port
Action '?' is using the same variable to select the BPS
number and the button number
Check the variables assigned to these fields in the
action properties
Trigger '?' requires input '?' on '?' to be configured as a
digital input or contact closure
The RIO's input has been configured incorrectly, see
Trigger '?' requires '?' to be configured as an Audio input
device
The RIO has been configured incorrectly, see
Trigger '?' uses frequency band '?' on '?' but that device
doesn't provide that band
Select a band that is available for that device, or
reconfigure the RIO, see
Condition '?' requires input '?' on '?' to be configured as a
digital input or contact closure
The RIO's input has been configured incorrectly, see
Condition '?' expects all inputs on '?' to be configured as
either digital inputs or contact closures
The RIO's input has been configured incorrectly, see
Condition '?' requires input '?' on '?' to be configured as an
analog input
The RIO's input has been configured incorrectly, see
Ethernet Bus '?' uses port '?'. This clashes with the
internal web server and will prevent correct operation of
controller '?'
Reconfigure the Ethernet bus to use a different port
Ethernet Bus '?' uses port '?'. This clashes with file trans-
fer and will prevent correct operation of controller '?'
Reconfigure the Ethernet bus to use a different port
Controller '?' is outputting KiNet so ensure the DHCP
server on protocol network interface is serving an IP
address on the same network as the patched power sup-
plies
Configure the DHCP server to use a 10.xxx.xxx.xxx
IP address
Controller '?' is outputting KiNET so ensure that the pro-
tocol network interface IP address is on the same network
as the patched power supplies
Reconfigure the Protocol port to use a
10.xxx.xxx.xxx IP address
Multiple KiNet power supplies have the IP address '?'
Reconfigure power supplies to use unique IP
addresses
Controller '?' is outputting KiNet so ensure that the con-
troller IP address is on the same network as the patched
power supplies
Reconfigure the Controller to use a 10.xxx.xxx.xxx
IP address