61
Using the Web Server
• Unless already done, please follow all the steps described
in section General Parameters on page 49 before
proceeding with the steps below.
• Still on the
Rover Setup page, in the Network pane, set the
following parameters:
–
Connection: Choose “Ethernet Ntrip Client - Port P”. As
a result, new fields appear in this pane that you should
set as instructed below:
–
Connect Now: Enable this option to allow the receiver to
establish the connection right after you have clicked
on
Configure.
–
Address, Port, Login, Password: Enter the information
allowing the receiver to connect to the NTRIP caster.
This information should have been passed on to you
earlier by the administrator of this service.
–
Load Source Table button: Click on this button after you
have entered the information about the NTRIP caster.
As a result, the list of available sources from this caster
appears just underneath. (See example below.)
Select the desired source by simply clicking on the
corresponding row. The resulting mount point then
appears in the
Mount Point field located above the Load
Source Table button.
–
Send NMEA: Check this button when the rover operates
in a VRS network so that it can return its position to the
network through an NMEA message. Keep it cleared in
all other cases. (This option is automatically enabled
when you select a mount point for which the NMEA