Spectra Precision ProFlex 800 Reference Manual User Manual
Page 169

155
Web Server Help Files Collection
Network
Use this area to declare the type of connection used by the
rover to acquire base data through a mobile communication
network or through the Internet. The content of this area
changes depending on your choice in the
Connection field.
If “Modem Direct IP - Port E” or “Ethernet Direct IP - Port P”
is selected, enter the following parameters:
RTS/CTS
Check this button to enable the RTS/CTS handshak-
ing protocol on the port. Clear it otherwise.
CTS
Parameter
Designation
$PASHS
Connection
Choose the type of network connection used in the
receiver:
• None: No network connection used.
• Modem Direct IP - Port E: The rover is connected to
the Internet via its internal modem using a Direct IP
connection.
• Modem NTRIP Client - Port E: The rover is con-
nected to the Internet via its internal modem as a
client for an NTRIP connection.
• Ethernet Direct IP - Port P: The rover is connected
to the Internet through its Ethernet port using a
Direct IP connection.
• Ethernet NTRIP Client - Port P: The rover is con-
nected to the Internet through its Ethernet port as a
client for an NTRIP connection.
MDM,..
NTR,PAR
Parameter
Designation
$PASHS
Connect
Now
Check this option if you want the connection to take
place just after you click on the Configure button.
MDM,DAL
Address
Enter the IP address or hostname (32 characters
max.) of the system the rover has to connect to.
DIP
Port
Enter the IP port number (0-65535) of the system the
rover has to connect to.
DIP
Login
If required, enter the login (20 characters max.)
through which the connection is allowed.
DIP
Password
If required, enter the password (20 characters max.)
through which the connection is allowed.
DIP
Parameter
Designation
$PASHS