Network

Use this area to declare the type of connection used by the
rover to acquire base data through a mobile communication
network or through the Internet. The content of this area
changes depending on your choice in the

Connection field.

If “Modem Direct IP - Port E” or “Ethernet Direct IP - Port P”
is selected, enter the following parameters:

RTS/CTS

Check this button to enable the RTS/CTS handshak-
ing protocol on the port. Clear it otherwise.

CTS

Parameter

Designation

$PASHS

Connection

Choose the type of network connection used in the
receiver:
• None: No network connection used.
• Modem Direct IP - Port E: The rover is connected to

the Internet via its internal modem using a Direct IP
connection.

• Modem NTRIP Client - Port E: The rover is con-

nected to the Internet via its internal modem as a
client for an NTRIP connection.

• Ethernet Direct IP - Port P: The rover is connected

to the Internet through its Ethernet port using a
Direct IP connection.

• Ethernet NTRIP Client - Port P: The rover is con-

nected to the Internet through its Ethernet port as a
client for an NTRIP connection.

MDM,..
NTR,PAR

Parameter

Designation

$PASHS

Connect
Now

Check this option if you want the connection to take
place just after you click on the Configure button.

MDM,DAL

Address

Enter the IP address or hostname (32 characters
max.) of the system the rover has to connect to.

DIP

Port

Enter the IP port number (0-65535) of the system the
rover has to connect to.

DIP

Login

If required, enter the login (20 characters max.)
through which the connection is allowed.

DIP

Password

If required, enter the password (20 characters max.)
through which the connection is allowed.

DIP

Parameter

Designation

$PASHS