Spectra Precision ProFlex 800 Reference Manual User Manual
Page 170

156
Web Server Help Files Collection
If “Modem NTRIP Client - Port E” or “Ethernet NTRIP Client
- Port P” is selected, enter the following parameters:
Differential Port
Use this area to indicate the way the rover should detect the
incoming differential data stream or streams. In Manual
mode, you will need to indicate the port(s) used.
Parameter
Designation
$PASHS
Connect
Now
Check this option if you want the connection to take
place just after you click on the Configure button.
NTR,MTP
Address
Enter the IP address of the NTRIP caster
NTR,PAR
Port
Enter the IP port number of the NTRIP caster
NTR,PAR
Mount Point
This field is automatically completed when selecting
a row in the open source table (see below).
Login
Enter the login allowing the receiver to establish the
connection with the NTRIP caster.
NTR,PAR
Password
Enter the password allowing the receiver to establish
the connection with the NTRIP caster.
NTR,PAR
Load
Source
Table
Once the IP address and IP port number of the
NTRIP server have been entered (see above), click
on the Load Source Table button to list the data
stream names available from the NTRIP caster.
Select one from the table. This will complete the
Mount field above automatically.
NTR,LOD
Send NMEA
If the rover operates in a VRS network, check this
button so the rover can return its position to the net-
work through an NMEA message. Keep it cleared in
all other cases.
NME,GGA
Parameter
Designation
$PASHS
Automatic
Check this option if you want the rover to detect the
incoming differential data stream(s) by itself.
CPD,REM
Manual
Check this option if you want to indicate the port(s) on
which the incoming differential data stream(s) is (are)
received.
CPD,REM