beautypg.com

Relevant query commands, See also, Atm,all: disabling all atom messages – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 337: Function, Command format, Relevant query command

background image

323

Set Command Library

Example

Enabling ATOM message type PVT on serial port A at a 1-
second output rate:

$PASHS,ATM,PVT,A,ON,1*0E

Relevant Query

Commands

$PASHQ,ATO

$PASHQ,ATM

See also

$PASHS,ATM,PER

$PASHS,ATM,ALL

ATM,ALL: Disabling All ATOM Messages

Function

This command disables all ATOM messages currently enabled
on the specified port.

Command Format

Syntax

$PASHS,ATM,ALL,c1,OFF[*cc]

Parameters

Example

Disabling all ATOM messages on port A:

$PASHS,ATM,ALL,A,OFF*4E

Relevant Query

Command

None.

See also

$PASHS,ATM

Parameter

Description

Range

c1

Port related to the ATOM message(s) you want
to disable.
• A, B, F: Serial port
• C: Bluetooth port
• I, I1-I9: Ethernet port
• E: Modem
• M, U: Internal memory (M), USB key (U)
• R: Data recording through session

A, B, C, E, F, I,
M, U, I1-I9, R

*cc

Optional checksum

*00-*FF