beautypg.com

Relevant query command, Pwr,slp: sleep mode, Function – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 440: Command format

background image

426

Set Command Library

Parameters

Example

Setting the thresholds to respectively 7 and 9 V:

$PASHS,PWR,PAR,7,9*41

Relevant Query

Command

$PASHQ,PWR

PWR,SLP: Sleep Mode

Function

This command is used to switch the receiver instantly to
sleep mode.

Command Format

Syntax

$PASHS,PWR,SLP,m1[*cc]
or
$PASHS,PWR,SLP,d2,m3[*cc]

Parameters

Examples

Setting the receiver to sleep mode for 5 hours:

Parameter

Description

Range

Default

f1

Battery voltage threshold, in volts, trigger-
ing a low-battery alarm

6.7-8.4

6.8

f2

External power voltage threshold, in volts,
triggering a low-power alarm

9.0-28.0

9.1

f3

Lower limit of DC voltage, in volts, con-
trolling automatic power on/off

9.0-36.0

9.0

f4

Upper limit of DC voltage, in volts, con-
trolling automatic power on/off

9.0-36.0

36.0

*cc

Optional checksum

*00-*FF

-

Parameter

Description

Range

m1

Time (hhmm) during which the receiver will stay in
sleep mode (min time: 5 minutes). The receiver will
be automatically awoken at the end of this time.

0005-9559

d2

Number of day in year when to wake up the receiver. 0-366

m3

Time in day when to wake up the receiver (hhmm). 0000-2359

*cc

Optional checksum

*00-*FF