Rec: enable/disable, start/stop raw data recording, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 455: Relevant query command, See also

441
Set Command Library
REC: Enable/Disable, Start/Stop Raw Data Recording
Function
This command allows you to enable, disable, start or stop raw
data recording. Raw data is recorded in the memory you
selected with the $PASHS,MEM command.
Command Format
Syntax
$PASHS,REC,c[*cc]
Parameters
Examples
Starting raw data recording:
$PASHS,REC,Y*54
Stopping raw data recording:
$PASHS,REC,N*43
Relevant Query
Command
$PASHQ,REC
See also
$PASHS,MEM
$PASHS,ATM
Parameter
Description
Range
c
Control character:
• Y: Yes. The receiver will immediately start
recording data. This option also enables data
recording at receiver power-up, i.e. recording will
start every time you turn the receiver on, even if
you stopped recording before the end of the pre-
vious session.
• N: No. The receiver will immediately stop record-
ing data. This option also disables data recording
at receiver power up, i.e. the receiver won’t
resume data recording when you next turn it on.
This is the default mode.
• S: Stop. The receiver will immediately stop
recording raw data. This option does not affect
the way the receiver operates at power-up.
• R: Restart. The receiver will immediately start
recording raw data. This option does not affect
the way the receiver operates at power-up.
Y, N, S, R
*cc
Optional checksum
*00-*FF