453

Set Command Library

Parameters

Parameter

Description

Range

Default

VER,d1

RINEX version:
• 0: RINEX 2.11
• 1: RINEX 2.11-Hatanaka
• 2: RINEX 3.01
• 3: RINEX 3.01-Hatanaka

1

0-3

CMP,d2

Compression:
• 0: None
• 1: TarZ

1

0-1

PER,d3

RINEX measurement period:
• 0: Period specified in G-file is used
• Other than 0: is the RINEX mea-

surement period actually used, in
seconds

0

0-60

GLO,s4

GLONASS conversion:
• ON: GLONASS measurements are

converted

• OFF: GLONASS measurements

are ignored

ON

ON, OFF

SBA,s5

SBAS conversion:
• ON: SBAS measurements are con-

verted

• OFF: SBAS measurements are

ignored

ON

ON, OFF

GAL,s6

GALILEO conversion:
• ON: Galileo measurements are

converted

• OFF: Galileo measurements are

ignored

OFF

ON, OFF

AGY,s7

Agency name

20 char. max.

OBN,s8

Observer name

20 char. max.

MNM,s9

Antenna marker name

60 char. max.

MNB,s10

Antenna marker number

20 char. max.

OBS,s11

Observation file comments

255 char. max.

GPN,s12

GPS Navigation file comments

255 char. max.

GLN,s13

GLONASS Navigation file comments 255 char. max.

SBN,s14

SBAS Navigation file comments

255 char. max.

GAN,s15

GALILEO Navigation file comments

255 char. max.

MET,s16

Meteo file comments

255 char. max.

SSM,s17

Sensor model

20 char. max.

SST,s18

Sensor type

20 char. max.

APR,f19

Accuracy of PR (pressure in mbar)

0.0-100.0

0.0

ATD,f20

Accuracy of TD (dry temperature in
degrees Celsius

0.0-100.0

0.0