beautypg.com

Met,intvl: query time interval for meteo data, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 417: Relevant query command, See also

background image

403

Set Command Library

MET,INTVL: Query Time Interval for Meteo Data

Function

This command is used to define the time interval through
which the receiver will regularly ask the meteorological unit
to return the current values of meteo data. The command also
specifies the ID of the receiver port used to communicate
with the meteorological unit.

By default, the receiver will query the meteorological unit
every 5 seconds once the receiver has notified the
meteorological unit, through the $PASHS,OUT,x,MET,ON
command,to start operating.

Command Format

Syntax

$PASHS,MET,INTVL,c1,d2[*cc]

Parameters

Example

Setting query interval to 10 seconds:

$PASHS,MET,INTVL,A,10*0C

Relevant Query

Command

$PASHQ,MET

See Also

$PASHS,MET,CMD

$PASHS,MET,INIT

$PASHS,OUT,x,MET

Parameter

Description

Range Default

c1

Receiver serial port connected to the meteoro-
logical unit.

A, B, F

d2

Query interval, in seconds

5-9999 5

*cc

Optional checksum

*00-*FF