Set Command Library
OUT,x,TLT: Starting Tiltmeter Data Acquisition
Function
This command is used to start the data processing in the
tiltmeter. The command also specifies the ID of the receiver
port used to communicate with the tiltmeter.
By executing the command, the tiltmeter is first initialized,
and then the receiver is allowed to send queries at regular
intervals of time, based on the preset value of query interval.
Command Format
Syntax
$PASHS,OUT,c1,TLT,s2[*cc]
Parameters
Example
Starting the tiltmeter connected to port A:
$PASHS,OUT,A,TLT,ON*1B
Relevant Query
Command
$PASHQ,TLT
See Also
$PASHS,TLT,CMD
$PASHS,TLT,INIT
$PASHS,TLT,PAR
$PASHS,TLT,INTVL
PAR,LOD: Configuring the Receiver From a PAR File
Function
This command configures the receiver in one step, using the
data stored in the specified PAR file. The PAR file may have
been saved previously to the receiver’s internal memory or on
a USB key.
Parameter
Description
Range
c1
Receiver serial port connected to the tiltmeter.
A, B, F
s2
Enable/disable processing in tiltmeter
ON, OFF
*cc
Optional checksum
*00-*FF