Function, Command format, Relevant query command – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 472: See also

458
Set Command Library
SES,AUT: Setting a Series of Sessions Automatically
Function
This command is used to set a series of sessions through an
automatic procedure. Sessions will have similar duration and
common recording rate. They will take place one after the
other with no idle time in between.
Command Format
Syntax
$PASHS,SES,AUT,d1,d2,d3,f4[*cc]
Parameters
Comments
• The command is NAKed if the number of sessions
multiplied by the session duration is greater than 24
hours.
• The command will overwrite all the previously defined
sessions with the new ones.
Example
Setting 24 sessions of one hour each (continuous, round-the-
clock operation) with 1-second recording rate:
$PASHS,SES,AUT,000000,24,0100,1*6A
Relevant Query
Command
$PASHQ,SES
See Also
$PASHS,SES,PAR
$PASHS,SES,DEL
$PASHS,SES,AUT
Parameter
Description
Range
Default
d1
Session start time (hhmmss)
000000-235959
000000
d2
Number of sessions.
1-96
24
d3
Session duration (hhmm)
0005-2400
0100
f4
Data recording rate used during
sessions, in seconds.
0.05 or 0.1-0.4 if [F]
option activated.
0.5-0.9
1-999
30
*cc
Optional checksum
*00-*FF