beautypg.com

Relevant query command, See also, Snm: signal-to-noise ratio mask – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 483: Function, Command format

background image

469

Set Command Library

Parameters

Example

Defining site name “ECC1”:

$PASHS,SIT,ECC1*63

Relevant Query

Command

$PASHQ,SIT

See also

$PASHS,REC

SNM: Signal-To-Noise Ratio Mask

Function

This command is used to mask the signal observations that
do not meet the minimum C/A code signal-to-noise ratio you
specify. This means that only the observations meeting this
requirement will be used in the PVT computation (all the
others will be rejected).

Command Format

Syntax

$PASHS,SNM,d1[*cc]

Parameters

Example

Setting the SNR mask to 45 dB.Hz:

$PASHS,SNM,45*08

Relevant Query

Command

$PASHQ,SNM

Parameter

Description

Range

s

Site name (or site ID), a 4-character string
where “*”, “.”, “/” and “\” are not allowed.

*cc

Optional checksum

*00-*FF

Parameter

Description

Range Default

d1

SNR mask, in dB.Hz

0-60

0

*cc

Optional checksum

*00-*FF