Dri: raw data recording rate, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 382: Relevant query command, See also, Dst: data stream connection modes

368
Set Command Library
DRI: Raw Data Recording Rate
Function
This command sets the recording rate for all raw data logged
in the internal or external memory. This rate can be
independent of the data output rate on a serial port.
Command Format
Syntax
$PASHS,DRI,f[*cc]
Parameters
Example
Setting the recording rate to 5 seconds:
$PASHS,DRI,5*33
Relevant Query
Command
$PASHQ,DRI
See also
$PASHS,ATM
$PASHS,RAW
$PASHS,REC
$PASHS,POP
DST: Data Stream Connection Modes
Function
This command is used to set up the type of TCP/IP
connection to be implemented for each available data
stream.
Whereas $PASHS,BDS is used to define the type of data
available on each Ix port, the present command allows you to
define the conditions in which each available data stream can
be acquired from a remote equipment through an IP
Parameter
Description
Range
Default
s
Raw data recording rate.
Setting $PASHS,POP to “20”
is a prior condition to operat-
ing at 0.05 s (20 Hz).
0.05 sec or 0.1-0.4 sec
if the [F] option is acti-
vated.
0.5-0.9 s
1-999 s
1 s
*cc
Optional checksum
*00-*FF