Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 460

446
Set Command Library
Command Format
Syntax
$PASHS,RNX,TYP,d1,d2[,d3][*cc]
Parameters
Parameter
Description
Range
Default
d1
Scenario number
See table below
4
d2
Output rate for observa-
tions, in seconds.
0.1-0.4 if [F] option activated.
0.5-0.9
1-1800
1
d3
Output rate for attributes
(receiver and antenna
names), in seconds.
0:Disabled
1-1800
31
*cc
Optional checksum
*00-*FF
Scenario
Number
Description
0
All available raw data in full presentation, full computed reference
position follows at each epoch. This scenario is not recommended
for use as differential protocol.
1
L1 pseudo-range and carrier phase in full presentation, extended
fixed position follows each 12 epochs.
2
L1 SNR, pseudo-range and carrier phase in full presentation,
extended fixed position follows each 12 epochs.
3
L1&L2 pseudo-range and carrier phase in full presentation, extended
fixed position follows each 12 epochs.
4
L1 &L2 SNR, pseudo-range and carrier phase in full presentation,
extended fixed position follows each 12 epochs.
100
L1&L2 compact pseudo-range and full carrier phase, extended fixed
position follows each 12 epochs, all the data are decimated in 5 times
compared to L1 carrier phase.
101
L1&L2 compact pseudo-range and compact carrier phase, extended
fixed position follows every 12 epochs, all the data are decimated in 5
times compared to L1 carrier phase. This scenario cannot be used
with a moving receiver.
201
Same as scenario 1, but extended computed reference position fol-
lows each epoch.
202
Same as scenario 2, but extended computed reference position fol-
lows each epoch.
203
Same as scenario 3, but extended computed reference position fol-
lows each epoch.
204
Same as scenario 4, but extended computed reference position fol-
lows each epoch.