Relevant query command, See also, Function – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 445: Command format

431
Set Command Library
Parameters
Example
Setting the data output rate to 2 seconds:
$PASHS,RAW,PER,2*44
Relevant Query
Command
$PASHQ,RAW
See also
$PASHS,RAW
$PASHS,RAW,ALL
$PASHS,POP
RCP,GBx: GLONASS Carrier Phase Biases for User-Defined
Receiver
Function
This set of two commands is used to define GLONASS carrier
phase biases for a given receiver. One command deals with
the GLONASS L1 band and the other with the GLONASS L2
band.
Command Format
Syntax
For the L1 band:
$PASHS,RCP,GB1,s1,f2,f3,f4,f5,f6,f7,f8,f9,f10,f11,f12,f13,f14,f15,f16,f17[*c
c]
For the L2 band:
$PASHS,RCP,GB2,s1,f2,f3,f4,f5,f6,f7,f8,f9,f10,f11,f12,f13,f14,f15,f16,f17[*c
c]
Parameters
Parameter
Description
Range
Default
f
Output rate, in seconds.
Setting $PASHS,POP to “20”
is a prior condition to operat-
ing at 0.05 s (20 Hz).
0.05 s or 0.1-0.4 s with
[F] option activated.
0.5-0.9 s
1-999 s
1 s
*cc
Optional checksum
*00-*FF
Parameter
Description
Range
s1
Name of user-defined receiver for which GLON-
ASS biases must be defined (case sensitive)
31 characters
max.