beautypg.com

1 trace view features – Teledyne LeCroy USB Protocol Suite User Manual (Voyager_Advisor T3_Mercury) User Manual

Page 70

background image

Teledyne LeCroy Corporation

Your First USB Recording

70

 

 

USB Protocol Suite User Manual

10. To save a current recording for future reference, select File > Save As on the Menu 

Bar.
OR

11. Click 

 on the Tool Bar to display the standard Save As window.

Give the recording a unique name and save it to the appropriate directory.

3.6.1

Trace View Features

After the recording terminates, the results display (see 

Figure 3.11 on page 70

).

The packet view display uses color and graphics to document captured traffic.

Packets are on separate rows, with individual fields both labeled and color‐
coded. 

Packets are numbered sequentially (as recorded), time‐stamped (with a resolu‐
tion of 2 ns on 3.0 signalling), and highlighted to show the transmitted speed 
(low‐speed, full‐speed, high‐speed, or superspeed).

You can name and save display formats for later use. 

Data fields can collapse to occupy minimal space in the display.

Figure 3.11: Trace View Display

You can start the application from the Desktop or from the installed directory. 

The display software can operate independently of the Analyzer. When used without the 
Analyzer, the program functions in a Trace Viewer mode to view, analyze, and print