beautypg.com

6 recording rules actions and action properties – Teledyne LeCroy USB Protocol Suite User Manual (Voyager_Advisor T3_Mercury) User Manual

Page 281

background image

    

USB Protocol Suite User Manual

281

Recording Rules Actions and Action Properties

 Teledyne  LeCroy Corporation

cases occurs, click the Momentary Disconnect button on the toolbar to cause a Disconnect/
Reconnect cycle of the VBus. If cycling does not work, disable and then re‐enable the xHCI Host 
controller driver in the Windows 7 Device Manager of your PDK. 

For Polarity Inversion, Downstream and/or Upstream, select On, Off, or Auto. For Simple 
Filters, you can Filter‐Out Logical Idles, Filter‐Out SKPs, Filter‐Out LUP/LDN,Filter‐Out 
ITP 
or Filter‐Out Bus Events (LFPS, EIdle, Term).

For Simple Triggers you can select the relevant Downstream and Upstream Triggers.

Select one of the Framing Error Triggers, Low Power States and CRC Error Triggers.

Truncate Data Fields 

Truncate the data fields in a Data payload Packet to the length specified in the pull‐down 
selection.

Check External Trigger Out with Sample Triggers if needed.

Note:

Truncating the payload will allow for more packets to fit in a trace, but it has the potential to 

prevent accurate decoding to higher layers (transfers, SCSI, etc).

10.6

Recording Rules Actions and Action Properties

Note:

For both USB 2.0 and USB 3.0.

The Actions are:

* Filter‐Out

Filtering Start‐of‐Frames (SOF's) in USB 2.0 captures can inhibit the ability of the 
software to decode upper layers (transfer and above) properly. The SOF is used as a 
delimiter of traffic in the analysis heuristics, and it's absence can cause a failure to 
recognize whether transactions should or should not be joined into a given transfer. 
If you are seeing transfers that do not appear correct (for example, at the SCSI level), 

Event

Description

Trigger**

Indicate Trigger event in the captured trace file.

Stop Recording*** 

Stop further recording once the trigger 
condition has been met. (USB 3.0 only)

Filter‐In

Include in the trace file the event specified (and 
no others).

Filter‐Out*

Exclude from the trace file the event specified.

Advance the Sequence

Go to the next state in this sequence
(sequence in which this action is located).

Restart All

Restart all sequences.

External Trigger Pulse 
HIGH

Send HIGH pulse on external trigger output.

Properties

Opens the Event Properties dialog box.