Teledyne LeCroy USB Protocol Suite User Manual (Voyager_Advisor T3_Mercury) User Manual
Page 41

USB Protocol Suite User Manual
41
Voyager M3/M3i Analyzer
Teledyne LeCroy Corporation
Note:
The rear has only a power connector.
WARNING:
Do not open the Voyager M3/M3i enclosure. No operator serviceable parts are
inside. Refer servicing to Teledyne LeCroy customer care.
Slow Flashing Yellow
Low Power States
Fast Flashing Yellow
Symbol Traffic, Training (TS1/TS2/TSEQ)
Solid Green
Link Traffic (U0) LUP, LDN
Blinking Green
TP's and DP's (actual traffic)
2.0
USB 2.0 unused
Note: USB 2.0 Link LEDs operate only while USB 2.0 Recording or Real‐
Time Statistics (RTS) is running.
USB 3.0 LEDs always operate, unless USB 3.0 has been disabled in the
Recording Options General Tab.
A (downstream)
MMCX plug connectors for interfacing
B (upstream)
with USB 3.0 signals
Tx +
Transmit pair
Rx +
Receive pair
Clock A (downstream)
Clock B (upstream)
MMCX plug connectors for interfacing with
external clock source or sink
In
Connects to an external reference clock
Out
Provides reference clock output
Trigger
In
SMA external trigger input. Note: Edge
detected. (Rising edge only) Voltage required:
Signal needs to be > 800mV to see a logic "1",
Signal needs to be < 400mV to see a logic "0" .
Maximum value of the external input signal
which can be input is 5 V. Minimum value is 0
V.
Out
SMA external trigger output.
Pulse Width = 280 ns. Pulse Voltage = 3.3
Volts into 1 MegOhms. Pulse Voltage = 2.7
Volts into 50 Ohms. Pulse is positive going.
USB
Type B connector for connection to host
machine
ETHERNET
Gigabit Ethernet connector for connection to
host machine