Expanding and Collapsing Data Fields

  Teledyne LeCroy Corporation

Along the top of the Raw Bits View is a linear strip of the logical bit values with 
corresponding field demarcations. Bit stuffing is in color. Below the logical bit values is a 
representation of the D+/D‐ signaling, complete with NRZ encoding. A scroll bar assists in 
navigation of larger packets. Use the two buttons under the label Packet to view previous 
or next packets. Two buttons under the label Zoom allow you to zoom in or out on 
packets.

5.6

Expanding and Collapsing Data Fields

You can expand a Data field to view it in greater detail or collapse it when you want a 
more compact view. 

5.6.1

Using the Expand/Collapse Data Field Arrows

To expand or collapse a Data Field, click the small triangular arrow on the left side of the 
data field.

5.6.2

Double-Clicking to Expand/Collapse Data Fields

You can expand or collapse Data fields by double‐clicking anywhere in the data field.