Teledyne LeCroy USB Protocol Suite User Manual (Voyager_Advisor T3_Mercury) User Manual
Page 217

USB Protocol Suite User Manual
217
Error Summary
Teledyne LeCroy Corporation
TP non‐zero
Reserved Field
A reserved value within a Transaction Packet has a non‐zero
value.
SKP Symbol error
An error was detected in the Skip Sequence.
Ctrl Endp Dir Error
The bit indicating the direction of this control stage is
inconsistent with the USB 3.0 Specification.
Missed DPH Error
The expected Data Packet Header was not captured as
expected.
Missed DPP Error
The Data Packet Payload was not seen after the Data Header
Packet as required by the USB 3.0 Specification.
Setup DP Error
The format of the Setup DPH is incorrect (Seq # !=0,
Datalength != 8, etc.).
Sequence Number
Error
The DP or TP Sequence Number is not in the order expected
according to the USB 3.0 Specification.
PTP Tra No
Command
No command seen in this PTP Transfer.
PTP Tra No Response No response seen in this PTP Transfer.
PTP Tra Id
Misordered
The Transfer ID's appear to be in the wrong order.
PTP Tra No
Operation code
The operation code is missing in this PTP transfer.
SCSI Op No
Command
The Command is missing from this SCSI Operation.
SCSI Op No Data
The Data is missing from this SCSI Operation.
SCSI Op status
Invalid Status is found for this SCSI Operation.
SCSI Op Invalid
OpCode
The SCSI OpCode is not supported by the current standards.
Error Type
Error Description