Error Summary
Teledyne LeCroy Corporation
TP non‐zero 
Reserved Field
A reserved value within a Transaction Packet has a non‐zero 
value.
SKP Symbol error
An error was detected in the Skip Sequence.
Ctrl Endp Dir Error
The bit indicating the direction of this control stage is 
inconsistent with the USB 3.0 Specification.
Missed DPH Error
The expected Data Packet Header was not captured as 
expected.
Missed DPP Error
The Data Packet Payload was not seen after the Data Header 
Packet as required by the USB 3.0 Specification.
Setup DP Error
The format of the Setup DPH is incorrect (Seq # !=0, 
Datalength != 8, etc.).
Sequence Number 
Error
The DP or TP Sequence Number is not in the order expected 
according to the USB 3.0 Specification.
PTP Tra No 
Command
No command seen in this PTP Transfer.
PTP Tra No Response No response seen in this PTP Transfer.
PTP Tra Id 
Misordered
The Transfer ID's appear to be in the wrong order.
PTP Tra No 
Operation code
The operation code is missing in this PTP transfer.
SCSI Op No 
Command
The Command is missing from this SCSI Operation.
SCSI Op No Data
The Data is missing from this SCSI Operation.
SCSI Op status
Invalid Status is found for this SCSI Operation.
SCSI Op Invalid 
OpCode
The SCSI OpCode is not supported by the current standards.