beautypg.com

Teledyne LeCroy USB Protocol Suite User Manual (Voyager_Advisor T3_Mercury) User Manual

Page 217

background image

    

USB Protocol Suite User Manual

217

Error Summary

 Teledyne  LeCroy Corporation

TP non‐zero 
Reserved Field

A reserved value within a Transaction Packet has a non‐zero 
value.

SKP Symbol error

An error was detected in the Skip Sequence.

Ctrl Endp Dir Error

The bit indicating the direction of this control stage is 
inconsistent with the USB 3.0 Specification.

Missed DPH Error

The expected Data Packet Header was not captured as 
expected.

Missed DPP Error 

The Data Packet Payload was not seen after the Data Header 
Packet as required by the USB 3.0 Specification.

Setup DP Error

The format of the Setup DPH is incorrect (Seq # !=0, 
Datalength != 8, etc.).

Sequence Number 
Error

The DP or TP Sequence Number is not in the order expected 
according to the USB 3.0 Specification.

PTP Tra No 
Command

No command seen in this PTP Transfer.

PTP Tra No Response No response seen in this PTP Transfer.
PTP Tra Id 
Misordered

The Transfer ID's appear to be in the wrong order.

PTP Tra No 
Operation code

The operation code is missing in this PTP transfer.

SCSI Op No 
Command

The Command is missing from this SCSI Operation.

SCSI Op No Data

The Data is missing from this SCSI Operation.

SCSI Op status

Invalid Status is found for this SCSI Operation.

SCSI Op Invalid 
OpCode

The SCSI OpCode is not supported by the current standards.

Error Type

Error Description