USB 3.0 Electrical Test Modes

 Teledyne  LeCroy Corporation

Figure 12.14: Usb 3 Trace to Exerciser Script Export Settings Dialog

8. Select from the desired options, click OK.
9. Click the Start Export button to begin export.
10. After exporting finishes, click Close to close the dialog.

12.13 USB 3.0 Electrical Test Modes

In the Electrical Test window, you can use Loopback mode and Compliance mode.

To access the Electrical Test window, you must connect to the Voyager system. 

12.13.1 Loopback Mode

The Voyager USB 3.0 Electrical Test window supports entry to the Polling.Loopback 
substate. For receiver testing, the device under test (loopback slave) is placed in a special 
test mode and echoes back a predefined loopback pattern. The Voyager system can 
initiate this special mode (loopback master) and generate the basic loopback pattern. The 
Voyager automatically monitors the received traffic for bit errors. 

Full compliance testing requires the addition of jitter tolerance measurements to the 
loopback stream. Specialized equipment, such as Teledyne LeCroy's PERT 
Receiver Tolerance Test system, should be used to introduce jitter and perform the full 
electrical layer compliance testing process.