beautypg.com

5 web management, 1 radius client configuration, 1 radius global configuration – Accton Technology ES4710BD User Manual

Page 529

background image

528

E

ES4710BD 10 Slots L2/L3/L4 Chassis Switch

20.5 WEB MANAGEMENT

Click “Authentication configuration”, to open authentication configuration management list.Users

may configure switch 802.1x authentication function.

20.5.1 RADIUS client configuration

Click “Authentication configuration”, “RADIUS client configuration”, to open Radius client

configuration management list Users may the configure switch Radius client.

20.5.1.1 RADIUS global configuration

Click “Authentication configuration”, “RADIUS client configuration”, “RADIUS global

configuration” to configure Radius global configuration information:
z

Authentication status – Enables, disables switch AAA authentication function. Disable radius
Authentication, disable AAA authentication function; Enable radius Authentication, enable

z

AAA authentication function. Equivalent to CLI command 20.2.2.1.

z

Accounting Status – Enables, disables switch AAA accounting function. Disable Accounting,
disable accounting function; Enable Accounting, enable accounting function. Equivalent to
CLI command 20.2.2.2.

z

RADIUS key – Configures RADIUS server authentication key.(includes authentication and
accounting)Equivalent to CLI command 20.2.2.19.

z

System recovery time (1-255 minutes) – Configures the recover time after RADIUS server
dead. Equivalent to 20.2.2.18.

z

RADIUS Retransmit times (0-100) – Configures the number of RADIUS authentication
message retransmit times. Equivalent to CLI command 20.2.2.20.

z

RADIUS server timeout (1-1000 seconds) – Configures RADIUS server timeout timer.
Equivalent to CLI command 20.2.2.20.

Example: Choose Authentication status as Enable radius Authentication, select Accounting Status as

Enable Accounting, configure RADIUS key as “aaa”, configure System recovery time as 10 seconds,

configure RADIUS Retransmit times as 5 times, configure RADIUS server timeout as 30 seconds,

and lastly, click Apply button. The configuration will then be applyied to the switch.