beautypg.com

Accton Technology ES4710BD User Manual

Page 482

background image

481

E

ES4710BD 10 Slots L2/L3/L4 Chassis Switch

Command Explanation
Interface Mode

[no] ip dvmrp enable

Enable DVMRP; the “no ip dvmrp enable
command disables DVMRP (required)

2. Configure connectivity with CISCO routers/switches
CISCO does not really implemented DVMRP, but provides connectivity with DVMRP. As CISCO
routers/switches send report packet but not probe packets, neighbor timeout issue should be
addressed in establish connectivity with CISCO routers/switches. The following command makes a
ES4710BD switch to decide the timeout of a neighbor by report packet intervals.

Command Explanation
Interface Mode

[no] ip dvmrp cisco-compatible
<A.B.C.D>

Enables connectivity with CISCO neighbor A, B,
C, D; the “no ip dvmrp cisco-compatible
command disables connectivity with CISCO
neighbors.


3. Configure DVMRP sub-parameters
(1) Configuring DVMRP interface parameters.

a. Configure metric value for DVMRP report packet
b. Configure DVMRP neighbor timeout time

Command Explanation
Interface Mode

ip dvmrp metric <metric_val>
no ip dvmrp metric

Sets interval for sending DVMRP report packets
in the interface; the “no ip dvmrp metric
command restores the default setting.

ip dvmrp nbr-timeout <time_val >
no ip dvmrp nbr-timeout

Sets timeout interval for DVMRP neighbors in the
interface; the “no ip dvmrp nbr-timeout
command restores the default setting.

(2) Configuring DVMRP global parameters.

a. Configure transmission interval of graft packets in DVMRP

b. Configure transmission interval of probe packets in DVMRP

c. Configure transmission interval of report packets in DVMRP

Command Explanation

Global Mode

ip dvmrp graft-interval <time_val>

no ip dvmrp graft-interval

Sets the interval for sending DVMRP graft

messages; the “no ip dvmrp graft-interval

command restores the default setting.

ip dvmrp probe-interval <time_val>

no ip dvmrp probe -interval

Sets the interval for sending DVMRP probe

messages; the “no ip dvmrp probe interval

command restores the default setting.