ES4710BD 10 Slots L2/L3/L4 Chassis Switch

Note:

&

Combo port is a conception involving the physical layer and the LLC sublayer of the datalink

layer. The status of a combo port will not affect any operation in the MAC sublayer of the

datalink layer and upper layers. If the bandwidth limit for a combo port is 1Mbps, then this

1Mbps applies to the active port of this combo port, regardless of the port type being copper or

fiber.

&

If a combo port connects to another combo port, it is recommended for both parties to use

copper-forced or fiber-forced mode.

&

Run “show interface” under Admin Mode to check for the active port of a combo port The

following result indicates if the active port for a combo port is the fiber cable port or copper

cable port: Hardware is Gigabit-combo, active is fiber (copper).

Example: setting ports 1/25 -28 to fiber-forced

Switch(Config)#interface ethernet 1/25-28

Switch(Config-Port-Range)#combo-forced-mode sfp-forced

7.2.1.2.3 flow control

Command: flow control

no flow control

Function: Enables the flow control function for the port: the “no flow control” command disables

the flow control function for the port.

Command mode: Interface Mode

Default: Port flow control is disabled by default.

Usage Guide: After the flow control function is enabled, the port will notify the sending device to

slow down the sending speed to prevent packet loss when traffic received exceeds the capacity of

port cache. ES4710BD’s ports support IEEE802.3X flow control; the ports work in half-duplex

mode, supporting back-pressure flow control. If flow control results in serious HOL, the switch will

automatically start HOL control (discarding some packets in the COS queue that may result in HOL)

to prevent drastic degradation of network performance.

Note: Port flow control function is NOT recommended unless the users need a slow speed, low

performance network with low packet loss. Flow control will not work between different cards in

the switch. When enable the port flow control function, speed and duplex mode of both ends should

be the same.

Example: Enabling the flow control function in ports 1/1-8.

Switch(Config)#interface ethernet 1/1-8

Switch(Config-Port-Range)#flow control