beautypg.com

7 ip igmp snooping vlan query robustness, 8 ip igmp snooping vlan query interval, 9 ip igmp snooping vlan query max-response-time – Accton Technology ES4710BD User Manual

Page 256

background image

255

E

ES4710BD 10 Slots L2/L3/L4 Chassis Switch

Parameters: is the VALN number specified.
Command mode: Global Mode
Default: IGMP Query is disabled by default.
Usage Guide: Before enabling the IGMP Query function for the specified VLAN, the switch must

have a corresponding VLAN configured and IGMP Snooping enabled. It should be
noted that this command cannot be used with ip igmp snooping vlan
command, i.e., either snooping or query can be enabled for one VLAN, but not both.

Example: Enabling the IGMP Query function for VLAN 100.
Switch(C

onfig)#ip igmp snooping vlan 100 query

11.2.2.7 ip igmp snooping vlan query robustness

Command: ip igmp snooping vlan query robustness

no ip igmp snooping vlan query robustness

Function: Enables the IGMP Query function for the specified VLAN: the “no ip igmp snooping

vlan query robustness command restores the default setting.

Parameters: <vlan-id> is the specified VLAN number; is robustness

parameter, the valid range is 2 to 10.

Command mode: Global Mode
Default: The default robustness parameter is 2.
Usage Guide: A larger robustness parameter means worse network conditions; smaller robustness

parameter means better network conditions. The user can set the robustness
parameter according to their network conditions.

Example: Setting the robustness parameter for the IGMP Query of VLAN 100 to 3.
Switch(C

onfig)#ip igmp snooping vlan 100 query robustness 3

11.2.2.8 ip igmp snooping vlan query interval

Command: ip igmp snooping vlan query interval

no ip igmp snooping vlan query interval

Function: Sets the IGMP Query interval for the specified VLAN; the “no ip igmp snooping vlan

query interval command restores the default setting.

Parameters: <vlan-id> is the specified VLAN number; is the query interval, valid

range is 1 to 65535.

Command mode: Global Mode
Default: The default interval is 125 seconds.
Example: Setting the IGMP Query interval for VLAN 100 to 60 seconds.
Switch(C

onfig)#ip igmp snooping vlan 100 query interval 60

11.2.2.9 ip igmp snooping vlan query max-response-time

Command: ip igmp snooping vlan query max-response-time

no ip igmp snooping vlan query max-response-time

Function: Sets the maximum IGMP Query response time for the specified VLAN; the “no ip igmp

snooping vlan query max-response-time command restores the default
setting.