5 ip port options, Userid, Network connection – Clear-Com HX System Frames User Manual
Page 89: Audio codec, Password, Voip caller, Remote ip address, Udp comm. port, Remote user id, Remote password
5.21.5
IP port options
Note:
IP Port Options are only available for IVC-32 cards.
The IP port options are as follows:
UserID
Panel ID required for the panel to log in to the system via the IVC-32 card. The user ID is
set in EHX and also entered on the panel for the panel to log in.
Note:
The password must not contain upper case letters.
Network connection
Selects the network connection type for an IP panel. Select from LAN (high speed), WAN
(intermediate) or Internet (low speed) from a drop-down menu. The default ins LAN.
Audio codec
Allows the codec (G.722) to be selected for IP connections.
Password
Panel password required for the panel to log in to the system via the IVC-32 card. The
password is set in EHX and also entered on the panel for the panel to log in.
VOIP caller
Enables the port as the initiator of the VOIP setting.
Remote IP address
The IP address for the remote device
UDP comm. port
The UDP communication port for the remote device.
Remote user ID
The unique user ID for the remote device. The maximum length for a user ID is ten
characters including spaces.
Note:
The user ID is case sensitive.
Remote password
The password for the remote device. The maximum length for the password is ten
characters including spaces.
Note:
The password is case sensitive.
Applies to:
Only available on Concert and V-Series IP panels.
89