beautypg.com

1 crosspoint settings and averaging, Crosspoint settings and averaging – Clear-Com HX System Frames User Manual

Page 269

background image

Figure 13-4 Crosspoint State Options

7)

To set the crosspoint level, select the level option on the menu to display the
crosspoint level slider and set the required level.

Figure 13-5 Crosspoint Level Slider

8)

Select the Refresh All option to update the display with the crosspoint settings
current on the matrix.

13.1.1

Crosspoint settings and averaging

In some cases the same port may be placed on a panel as different key more than once,
for example on different shift pages (multiple instances of the port). If these instances of
the port or keys have been set up with different audio levels then the level used on any of
keys connected to the port is the average of the levels of all the instances on the panel.
This is to prevent a situation where the audio level from the same port may vary greatly
between different keys assigned to that port depending on how the different keys have
been set up.

To improve the performance of the level averaging on I-Series panels the crosspoint range
for these panels is larger than previously. The preset levels in the matrix for I-Series
panels are:

• -30.2 dB
• -24.1 dB
• -18.1 dB
• -12.1 dB
• -9.2 dB
• -6.0 dB
• -3.9 dB
• -2.1 dB
• 0 dB
• 1.1 dB

269

Eclipse EHX Software User Guide