beautypg.com

2 intelligent linking (trunking), Intelligent linking (trunking) – Clear-Com HX System Frames User Manual

Page 242

background image

2)

From the context menu, select Delete Matrix from Project.

The matrix is deleted from the current project and removed from the layout pane.

10.1.5

Uploading the last downloaded configuration from the matrix

To upload the last downloaded configuration from the matrix:

1)

Right-click on the matrix.

2)

From the context menu, select Configuration > Upload Configuration from
Matrix
.

The last downloaded configuration is uploaded and added to the currently
selected slot on the matrix.

Note:

The Upload Configuration functionality is not available over a serial connection between
the Eclipse HX matrix and the EHX PC.

10.2

Intelligent linking (trunking)

As many as 64 separate Eclipse HX-Omega, Eclipse HX-Median, Eclipse HX-Delta and
Eclipse HX-PiCo system matrices can be intelligently linked, using dedicated audio trunk
lines and an Ethernet network. Audio travels between the matrices on the dedicated trunk
lines, while control data travels on the Ethernet network.

You can intelligently link Eclipse HX matrices using:

• Fiber-optic connections (using E-FIB fiber cards).
• Four-wire connections (using MVX-A16 analog cards).
• E1/T1 connections (using E-QUE cards).
• MADI connections (using E-MADI64 cards). When using E-MADI64 cards, ensure

that Trunk Port 1 on the first card is connected to Trunk Port 1 on the second
card, and similarly for Trunk Port 2.

• IP trunks/directs between two IVC-32 cards in separate matrices (see 5.21.5 IP

port options

Note:

Fiber, E1/T1, MADI and IP trunks/directs linking is only available to Eclipse HX-Omega,
Eclipse HX-Median and Eclipse HX-Delta matrices.

You can intelligently link Eclipse HX-PiCo matrices using:

• Four-wire connections.
• The PiCo-link to PiCo-link.

Note:

PiCo-link is only available for Eclipse HX-PiCo to Eclipse HX-PiCo connections. The PiCo-
link does not support hopping.

The sections below on Fiber trunking and Four-wire trunking provide a basic overview of
the intelligent linking process.

• The relevant matrix user guide.
• The Eclipse HX Installation Guide.

242