E-madi64 card properties, 3 upgrading the e-madi64 card firmware, Upgrading the e-madi64 card firmware – Clear-Com HX System Frames User Manual
Page 128
• The Talk / Listen label as defined in EHX.
E-MADI64 card properties
Card Properties permits sample rate selection when synching to video signals. The E-
MADI64 card must be configured before it can be used when not using the Word Clock
Source Sync.
Card Properties always defaults to the E-MADI64 standard for the number of channels.
To set the sample rate parameters, click Card Properties on the lower right of the Matrix
Hardware display.
The following dialog is displayed:
Figure 5-34 MADI Channel Sample Rate
E-MADI channel mode
Sample rate
Configurable ports
32
96K
32
56
44.1K or 48K
56
64
44.1K or 48K
64, 32 or 16
Table 5-4 E-MADI Channel modes
5.43.3
Upgrading the E-MADI64 card firmware
You can upgrade the following E-MADI64 code with EHX:
• H8 application code (*.fwc format file).
• DSP code (*.fwc format file).
• FPGA code.
The boot code file (*.mot) is upgraded using the Renesas Flash Development Toolkit 3.4
Basic (FDT), not EHX. The FPGA code can also be upgraded using Xilinx iMPACT
programming software.
Note:
For detailed upgrade procedures and information, including upgrades that you cannot
perform in EHX, see the Eclipse HX Upgrade Guide.
To upgrade E-MADI64 H8, DSP or FPGA code (for all the E-MADI64 cards) using EHX:
1)
Ensure that you have the following equipment:
Equipment
Description / Notes
PC with an Ethernet or serial port
-
EHX software
EHX must be installed and configured
Ethernet or serial connection
For the matrix to PC connection
128
Eclipse EHX Software User Guide