1 adding an e-fib card, 2 removing an e-fib card, 3 configuring an e-fib card – Clear-Com HX System Frames User Manual
Page 103: Adding an e-fib card, Removing an e-fib card, Configuring an e-fib card
5.24.1
Adding an E-FIB card
To add an E-FIB card:
1)
In Hardware > Cards and Ports, navigate to an available slot number (marked
Empty). Do either of the following:
• Double click the slot.
• Right click the slot and select Set Card Type.
2)
A drop-down menu is displayed, listing the available card types. Select either E-
FIB (Fiber) or E-FIB (Redundant).
Note:
Only one E-FIB (Fiber) and one E-FIB (Redundant) card can be added. Clear-Com
recommends that E-FIB cards are fitted to slots 6 and/or 7 of Eclipse HX-Median matrices,
slots 14 and/or 15 of Eclipse HX-Omega matrices and slot 4 of Eclipse HX-Delta matrices.
Figure 5-10 E-FIB Fiber Card Selection
5.24.2
Removing an E-FIB card
To remove an E-FIB card:
1)
In Hardware > Cards and Ports, navigate to the slot number of the E-FIB card
you want to delete. Do either of the following:
• Double click the slot.
• Right click the slot and select Set Card Type.
2)
A drop-down menu is displayed, listing the available card types. Select Empty.
A warning dialog is displayed. To confirm the deletion, click Yes.
5.24.3
Configuring an E-FIB card
The E-FIB card provides a single fiber port that can be configured to have Talk and Listen
labels and a description.
103
Eclipse EHX Software User Guide