1 main controller for pgm1, 2 main controller for pgm2/3/4, 13 special control settings – EVS MulticamLSM Version 9.00 - March 2008 User's Manual User Manual
Page 46: Pgm1, Pgm2/3/4, Ontroller for

EVS
Multicam - User Manual
EVS Broadcast Equipment SA – March 2008
Version 9.00
37
4.13
SPECIAL CONTROL SETTINGS
Special Control Settings p.7.2
Main RS422 Second. RS422
PGM1: EVS Remote -- [F5]Sony BVW75 04
PGM2:[F2]EVS Remote –- [F6]Sony BVW75 05
PGM3:[F3]EVS Remote –- [F7]---------- --
PGM4:[F4]EVS Remote –- [F8]---------- --
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
This page is used to define which device/controller can control which PGM
channel. For each PGM channel, you must define the main controller,
selecting from the list defined on page 7.1.
• In LSM mode, the main controller for PGM1 must always be an EVS
remote. This can not be changed by the operator.
• If the main controller is an EVS Remote, the RS422 port will be
automatically assigned and is not specified by the operator.
• If the main controller is an EVS remote, it is then possible to specify a
secondary controller for that channel, that can be a protocol defined on
page 7.1. The EVS remote controlling that channel can then decide at
any time to pass the control to, or to retrieve the control from the
secondary controller.
• Like for page 7.1, all EVS remotes must be the first in the list of Main
controllers, without gap. It is not allowed to have a protocol preceding
an EVS remote in this list.
• A protocol (other than EVS AVSP or EVS IPDP protocols) can only be
assigned to 1 channel at a time.
• EVS AVSP and IPDP protocols can be assigned to several channel
simultaneously. If you need to assign some channels to an AirBox, you
must set the main controller for these channels to EVS AVSP. If you
need to assign some channels to an IP Director, you must set the main
controller for these channels to EVS IPDP.
4.13.1
M
AIN
C
ONTROLLER FOR
PGM1
Possible values: EVS Remote
When working in LSM base configuration, the PGM1 main controller must
always be an EVS Remote. No other possible selection
4.13.2
M
AIN
C
ONTROLLER FOR
PGM2/3/4