11.90
2 Operation
2.1.1 SINUMERIK 810T operator interface
with integrated machine control panel
Feed or rapid traverse override decrease / increase
The two keys make it possible for you to decrease or increase the
programmed feedrate value ”F” (with reference to 100% value).
The value set with these keys is displayed as an absolute value and
as a percentage.
Operate the
key quickly.
The feedrate is decreased in the following steps:
– by
5 %,
in the feed range
120 %
to 70 %
– by 10 %,
in the feed range
70 %
to 10 %
– by
2 %,
in the feed range
10 %
to
2 %
– by
1 %,
in the feed range
2 %
to
0 %
Continuous operation causes the feedrate to be decremented in
steps until the end value 0% (standstill) is reached.
Operate the
key quickly.
The feedrate is increased in the following steps:
– by
1 %,
in the feed range
0 %
to
2 %
– by
2 %,
in the feed range
2 %
to 10 %
– by 10 %,
in the feed range
10 %
to 70 %
– by
5 %,
in the feed range
70 %
to 120 %
Continuous operation causes the feedrate to be incremented in
steps until the end value 120% is reached.
The increments specified apply to standard machine
data.
Socket connector for universal interface
Beneath the cover hinged on the left, you will find a 25-pole socket
for D-type sub-miniature connectors.
Via this V.24 (RS232) / 20 mA interface, you can transfer serial data
to or from peripheral devices.
14
o
o
o
o
o
o
o
o
o
o
o
o
25
1
o
o
o
o
o
o
o
o
o
o
o
o
o
13
For details of transmission data see Section 6.3 (Setting data), and for device connection see
Section 6.4 (Device connection data).
For details of the correct cables see: ”SINUMERIK System 800”, Configuring Instructions /
Universal Interface.
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
2-23
SINUMERIK 810T, GA3 (BN)