Siemens Sinumerik 810T User Manual
Page 283
01.93
6 Data Interfaces
6.3 Assignment of the setting data for the connection of peripheral devices
6.3
Assignment of the setting data for the connection of peripheral
devices
Before you connect a particular device to interface 1 (or interface 2), you must assign the
setting data bits of the setting data defined in the following tables.
For that purpose, you call up the relevant Setting Data number (SD no.) - as described in
Section 3.1.15.1.
The table only shows the setting data numbers (SD no.) for the connection of the respective
device to interface 1 (or 2).
Setting data number (SD no.) and setting data bits, dependent on type of peripheral device
Peripheral
device
Ident. of the
device type
(CRT display)
Required setting
data bits (binary
code)
SD no.
Inter-
face
1
Inter-
face
2
RTS LINE
SINUMERIK
Reader:T40,T50,
T60, RS232C (V.24),
9600 baud
5010
5011
5018
5019
0000 0000
1100 0111
SINUMERIK WS800,
RS232C (V.24)
20 mA
9600 baud
RTS LINE
5010
5011
5012
5013
5018
5019
5020
5021
0000 0000
1100 0111
0000 0000
1100 0111
PLC PROG.
5010
5011
5018
5019
0000 0100
0000 0111
RTS LINE
5010
5011
5012
5013
5016
5028
5018
5019
5020
5021
5024
5028
Siemens
Programmer
PG 675, RS232C
(V.24), 1200 baud
Interface printer
0000 0000
1100 0100
0000 0000
1100 0100
0010 1000
0000 0011
Siemens
Programmer
PG 615 U
20 mA, 9600 baud
PLC PROG.
5010
5011
5018
5019
0000 0100
0000 0111
Siemens-
Page Printer PT80
20 mA, RS232C
(V.24), 300 baud
RTS LINE
5010
5011
5012
5013
5018
5019
5020
5021
0000 0000
1100 0010
0000 0000
1100 0010
Siemens
Programmer
PG 685/675/670/730/750
20 mA, 9600 baud
PLC S5 interface
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
6-3
SINUMERIK 810T, GA3 (BN)