beautypg.com

Siemens Sinumerik 810T User Manual

Page 139

background image

3 Operating Sequences

09.91

3.1.9 TRANSMIT coordinate transformation

State / event matrix for transformation selection and deselection:

Note

1)

Case 1:

Transformation deselection on RESET: RESET is caused by pressing the RESET key, part programm

(PP) end and mode change except REFPOINT.

Case 2:

No transformation deselection on RESET: generally transformation modal except for REFPOINT.

Ereignis

Automatic

passive

Automatic

active

JOG

JOG

(Automatic

interrupted)

Automatic

interrupted

NC Start

Automatic

active

Automatik

active

NC Stop

Automatic

interrupted

Change to

JOG

JOG

JOG

(Automatic

interrupted)

JOG

(Automatic

interrupted)

Change to

AUTOMATIC

Automatic

passive

Automatic

interrupted

RESET

Automatic

passive

1)

Deselec-

tion of

transform.

Automatic

passive

1)

Deselec-

tion of

transform.

JOG

1)

Deselec-

tion of

transform.

JOG

1)

Deselec-

tion of

transform.

Automatic

passive

1)

Deselec-

tion of

transform.

Change to

REFPOINT

Deselection

of transform.

Deselection

of transform.

Deselection

of transform.

Deselection

of transform.

Deselection

of transform.

State

Event

Explanations of the state/event matrix:

The fields within the matrix contain the state subsequent to the event and information on the
transformation state.

“AUTOMATIC passive” state:
No program is being executed (Reset).

“AUTOMATIC active” state:
The program is being executed (program running).

“JOG” state:
You can traverse manually in the mode “JOG”, “INC” or “REPOS”.

“JOG” (AUTOMATIC interrupted) state:
The program was interrupted and the “JOG” state selected.

“AUTOMATIC interrupted” state:
The programm was interrupted, without leaving the “AUTOMATIC” mode (NC Stop).

3-38

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)