Siemens Sinumerik 810T User Manual
Page 265
4 Monitoring Functions
01.93
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
2153
”Control loop spindle HW”
Reason:
Effect:
Remedy:
As for alarm 132*
– Inhibiting of NC START
– Operation is brought to a defined standstill
As for alarm 132*
Alarm No.
Alarm Text:
2154
”Spindle measuring system dirty”
Reason:
Effect:
Remedy:
On measuring systems with a contamination signal, the measuring
system has signalled a fault to the NC
Inhibiting of NC START
Check the measuring system
Alarm No.
Alarm Text:
2155
”Option M19 not available”
Reason:
Effect:
Remedy:
”M19 S ...” has been programmed, although this function is not
present
Inhibiting of NC START
– Correct program
– Retrofit option ”M19”
Alarm No.
Alarm Text:
2160
”Scale factor not allowed”
Remedy:
Modify scale factor
Alarm No.
Alarm Text:
2161
”Scale change not allowed”
Remedy:
Correct scale modification
Alarm No.
Alarm Text:
2171
”Approach not possible”
Remedy:
Correct approach block
Alarm No.
Alarm Text:
2172
”Retract not possible”
Remedy:
Correct retraction block
Alarm No.
Alarm Text:
2173
”Wrong approach/retract plane”
Remedy:
Correct approach/retraction plane
Alarm-Nr.
Alarm-Text:
2183
”Axis is not a rotary axis”
Reason:
Effect:
Remedy:
The axis must be declared a rotary axis in MD 564*, bit 5.
NC Start and NC READY 2 disabled.
Set MD 564*, bit 5=1.
4-22
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)