4 Monitoring Functions

01.93

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

2153

”Control loop spindle HW”

Reason:
Effect:

Remedy:

As for alarm 132*
– Inhibiting of NC START
– Operation is brought to a defined standstill
As for alarm 132*

Alarm No.

Alarm Text:

2154

”Spindle measuring system dirty”

Reason:

Effect:
Remedy:

On measuring systems with a contamination signal, the measuring
system has signalled a fault to the NC
Inhibiting of NC START
Check the measuring system

Alarm No.

Alarm Text:

2155

”Option M19 not available”

Reason:

Effect:
Remedy:

”M19 S ...” has been programmed, although this function is not
present
Inhibiting of NC START
– Correct program
– Retrofit option ”M19”

Alarm No.

Alarm Text:

2160

”Scale factor not allowed”

Remedy:

Modify scale factor

Alarm No.

Alarm Text:

2161

”Scale change not allowed”

Remedy:

Correct scale modification

Alarm No.

Alarm Text:

2171

”Approach not possible”

Remedy:

Correct approach block

Alarm No.

Alarm Text:

2172

”Retract not possible”

Remedy:

Correct retraction block

Alarm No.

Alarm Text:

2173

”Wrong approach/retract plane”

Remedy:

Correct approach/retraction plane

Alarm-Nr.

Alarm-Text:

2183

”Axis is not a rotary axis”

Reason:
Effect:
Remedy:

The axis must be declared a rotary axis in MD 564*, bit 5.
NC Start and NC READY 2 disabled.
Set MD 564*, bit 5=1.

4-22

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)