beautypg.com

5 maintenance, 1 operating data, 2 handling the modules – Siemens Sinumerik 810T User Manual

Page 277: 5maintenance

background image

11.90

5 Maintenance

5.1 Operating data

5

Maintenance

5.1

Operating data

Humidity content
to DIN 40040

F

Air pressure

860 to 1080 hPa

Shockproof, dustproof and waterproof
to DIN 40050:

Operator panel

IP 54

External machine control panel

IP 54

5.2

Handling the modules

Modules/components carrying this warning symbol (yellow
hand on a black triangle, with stripe through) are suscep-
tible to electrostatic discharge.

• Electronics modules must not be touched unless it is absolutely vital for work to

be done.

• Before touching a module, any static in the body must be discharged. The

easiest way to do this is by touching a conductive, earthed part of the structure
(e.g. bare metal parts of the cubicle, socket earth contact).

• Modules should not be brought into contact with materials that are good

insulators (e.g. plastic foil, insulated desk tops, clothing made from synthetic
fibres).

• Modules should only be laid on conductive surfaces.

• Modules should only be removed or replaced with the power off.

Therefore, please pay attention to the following guidelines:

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

5-1

SINUMERIK 810T, GA3 (BN)