11.90

3 Operating Sequences

3.2.11 ”Actual value setting” mode (”PRESET”)

and

PRESET

Operate the operating mode selection key in
the integrated machine control panel, and
then the ”PRESET” softkey or ...

... set the operating mode selector switch on
the external machine control panel to this
symbol.

or

Sequence of operation

This input form with the input field
marked in inverse video appears.

(( 810T))
(( Bild 8 von Druckerei

einmontieren

Using the keyboard, enter number ”0” into the
”offset number” input field, and store it using the
input key.

1. ”PRESET offset” without inclusive calculation of the tool offset

First enter the designation of the desired axis - in
this example ”X” for the X axis. Then assign this
axis the corresponding value of the ”PRESET
offset” using the numerical keys and finally
operate the ”STORE” softkey.

0

S

=

H

STORE

H

X

7

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-129