3 display representation – Siemens Sinumerik 810T User Manual
Page 243
4 Monitoring Functions
11.90
4.3 Display representation
4.3
Display representation
There are 4 types of display representation:
•
Example of display representation type A
Valid for alarm numbers 0 .... 39 und 2000 ...... 2999 (partly)
max. 28 characters for
explanatory text.
2152 ORD 2 Spindle speed too high
max. 5 characters for serial number
ORD 1 ..... ORD99
(the serial number shows in what order the alarms
have occurred).
here: alarm 2152 as the second alarm)
(after the control has been switched on)
max. 4 characters for alarm number
•
Example of display representation type B
Valid for alarm numbers 1000 ...... 1963
max. 28 characters for
explanatory text
116*
ORD12
Contour Monitoring
max. 5 characters for serial number
ORD 1 ... ORD99
(the serial number shows in what order the alarms
have occurred)
here:
alarm 116* as the twelfth alarm)
(after the control has been switched on)
max. 4 characters for alarm number;
the ”*” stands for:
”0” 1st axis
”1” 2nd axis
”2” 3rd axis
”3” 4th axis
”4” 5th axis
4-2
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)