4 Monitoring Functions
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
2078
”Incorrect input parameter”
Reason:
Effect:
Remedy:
– Programmed parameter sequence not allowed
– Parameter sequence not complete for the described contour
As for alarm 2072
As for alarm 2072
Alarm No.
Alarm Text:
2081
”CRC not allowed”
Reason:
Remedy:
With TNRC/CRC selected (G41/G42), the following functions cannot
be programmed:
G33, G34, G35; G58; G59, G92, M19 S ...
First program cancellation of TNRC/CRC
with G40 or D0
Alarm No.
Alarm Text:
2082
”CRC plane not determinable”
Reason:
Remedy:
The axes for the selected CRC/TNRC plane do not exist
Select correct plane with G16
Alarm No.
Alarm Text:
2087
”Coordinate rotation not allowed”
Remedy:
Check NC program
Alarm No.
Alarm Text
2088
”Battery alarm abs. submod. 1”
Reason:
Remedy:
Battery voltage is too low. Battery test is performed every 10 min.
Replace battery module on absolute encoder module 1 while the
control is switched on.
Alarm No.
Alarm Text
2089
”Battery alarm abs. submod. 2”
Reason:
Remedy:
Battery voltage is too low. Battery test is performed every 10 min.
Replace battery module on absolute encoder module 2 while the
control is switched on.
Alarm No.
Alarm Text:
2152
”Spindle speed too high”
Reason:
Remedy:
The actual spindle speed is higher than that set in machine data.
– Program a smaller S value
– G92 S ... with v constant
– Search for a block number in the ”EDIT” mode (”AUTOMATIC”
mode)
Check or inform Service
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
4-21