background image

09.91

4 Monitoring Functions

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

2078

”Incorrect input parameter”

Reason:

Effect:
Remedy:

– Programmed parameter sequence not allowed
– Parameter sequence not complete for the described contour
As for alarm 2072
As for alarm 2072

Alarm No.

Alarm Text:

2081

”CRC not allowed”

Reason:

Remedy:

With TNRC/CRC selected (G41/G42), the following functions cannot
be programmed:
G33, G34, G35; G58; G59, G92, M19 S ...
First program cancellation of TNRC/CRC
with G40 or D0

Alarm No.

Alarm Text:

2082

”CRC plane not determinable”

Reason:
Remedy:

The axes for the selected CRC/TNRC plane do not exist
Select correct plane with G16

Alarm No.

Alarm Text:

2087

”Coordinate rotation not allowed”

Remedy:

Check NC program

Alarm No.

Alarm Text

2088

”Battery alarm abs. submod. 1”

Reason:
Remedy:

Battery voltage is too low. Battery test is performed every 10 min.
Replace battery module on absolute encoder module 1 while the
control is switched on.

Alarm No.

Alarm Text

2089

”Battery alarm abs. submod. 2”

Reason:
Remedy:

Battery voltage is too low. Battery test is performed every 10 min.
Replace battery module on absolute encoder module 2 while the
control is switched on.

Alarm No.

Alarm Text:

2152

”Spindle speed too high”

Reason:

Remedy:

The actual spindle speed is higher than that set in machine data.
– Program a smaller S value
– G92 S ... with v constant
– Search for a block number in the ”EDIT” mode (”AUTOMATIC”

mode)

Check or inform Service

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-21

SINUMERIK 810T, GA3 (BN)