11.90
3 Operating Sequences
3.2.3 Influencing ”AUTOMATIC” operation
3.2.3
Influencing ”AUTOMATIC” operation
Influencing ”AUTOMATIC” operation (e.g. through programmed functions), is displayed in the
first line of the CRT display.
Display:
STOP: AUTO INTERRUPTED
Interruption of ”AUTOMATIC” operation (program hold),
see Section 3.2.3.4 ”Program Interruption”.
Display:
HOLD: SINGLE BLOCK
The single block has been processed
(with switch position ”Single block - ON”).
Display:
STOP: PROG. STOP M00, M01
Programmed interruption of the program process
with ”Program start”
processing of the program
is continued.
Display:
STOP: READ-IN ENABLE
Read enable is a PLC output signal. When the read enable signal is
removed, the processing of the current NC block is finished. The next
program block is not transferred for processing.
Display:
HOLD: DWELL TIME
Processing of the program is interrupted for the duration of the
programmed dwell time.
Note:
”Feed hold” is not displayed on the CRT!
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
3-93