beautypg.com

Siemens Sinumerik 810T User Manual

Page 30

background image

2 Operation

09.91

2.1.1 SINUMERIK 810T operator interface

with integrated machine control panel

Acknowledge alarm

Actual position in double height characters

When you operate this key, the CRT display of ”Actual position” for the
” X”, ”Z” ( and ”Q1, Q2, ...,” when present ) axes is shown in double-
height characters. Axes 3-7 can be displayed with the ”page down”
function.

The ”Distance to go” display remains in normal character size.
The CRT information previously displayed is faded out.
Further operation of the key will take you back to the previous display
(with normal character size).

(( 810T))
(( Bild 1 von Druckerei

einmontieren))

With the operation of this key:

you acknowledge the information from the NC diagnostics, displayed
on the second line of the CRT display (see Section 2.1.1.1)

Fault message text

Fault message number

for message

nos.

3000 .... 3094

and

nos.

6000 .... 6163

Program operation is not interrupted!

you clear the red fault LED

on the display panel
(see Section 2.1.1.2)

?

If you set setting data 5001 bit 0, the actual value display refers to the

workpiece zero and not to the reference point, i.e. the zero offset and the

tool offsets are not displayed.

2-14

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)