2 Operation
09.91
2.1.1 SINUMERIK 810T operator interface
with integrated machine control panel
Acknowledge alarm
Actual position in double height characters
When you operate this key, the CRT display of ”Actual position” for the
” X”, ”Z” ( and ”Q1, Q2, ...,” when present ) axes is shown in double-
height characters. Axes 3-7 can be displayed with the ”page down”
function.
The ”Distance to go” display remains in normal character size.
The CRT information previously displayed is faded out.
Further operation of the key will take you back to the previous display
(with normal character size).
(( 810T))
(( Bild 1 von Druckerei
einmontieren))
With the operation of this key:
•
you acknowledge the information from the NC diagnostics, displayed
on the second line of the CRT display (see Section 2.1.1.1)
–
Fault message text
–
Fault message number
for message
nos.
3000 .... 3094
and
nos.
6000 .... 6163
Program operation is not interrupted!
•
you clear the red fault LED
on the display panel
(see Section 2.1.1.2)
?
If you set setting data 5001 bit 0, the actual value display refers to the
workpiece zero and not to the reference point, i.e. the zero offset and the
tool offsets are not displayed.
2-14
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)