15 data input/data output – Siemens Sinumerik 810T User Manual
Page 180
09.91
3 Operating Sequences
3.1.14 “SIMULATION”
Example of the simulation of a part program ( ” % 88 ” ):
PART PROGRAM % 88
N05 M3 S1500 LF
N10 T4 D2 G42 G0 X0 Z100 LF
N15 G1 F1 X10 LF
N20 G3 X30 Z90 I0 K-10 LF
N25 G1 X45 Z30 LF
N30 G2 B5 A110 X80 Z20 LF
N35 G1 Z10 LF
N40 X100 LF
N45 G0 X300 Z300 LF
N50 M30 LF
The following display appears:
%88
Part program no.
N . .
Block number
L . .
Subroutine no.
P . .
Subroutine passes
X . ., Z . .,
Current axis values
X67.300
Simulation area for ”X”
Z120.000
Simulation area for ”Z”
F . .
Current feedrate
T, D, H, M, S functions are not displayed.
Any subroutine nesting is simulated, but not
displayed.
((Bild 810T/35 einmontieren))
3.1.15 Data input/data output
For the input and output of data you will find a RS232C (V.24)/20 mA interface (=Interface 1,
with variable device connections possible) on the front of the operating panel.
A further RS232C (V.24) interface (=Interface 2, with fixed assignment for the connection of
a particular device) is located at the back of the control.
The second RS232C (V.24) interface is only available
with option ”C62”.
Fixed interface data are defined for the interfaces. These data can be modified by calling the
”SETTING DATA” function.
Modification of the interface data - especially for interface no. 1 - is necessary for example,
when a different device is interfaced to the SINUMERIK 810T (punch, tape reader, program-
mer, etc.)
You will find the necessary information for setting/modifying the setting data bits in Section
3.1.15.1 (Setting data bits) and Section 6.3 (Assignment of the setting data for the connection
of peripheral devices).
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
3-77
SINUMERIK 810T, GA3 (BN)