Siemens Sinumerik 810T User Manual
Page 128
09.91
3 Operating Sequences
3.1.6 Setting data: ”R PARAMETERS”, ”SPINDLE”, ”AXIAL”, ”ANGLE OF ROTATION”, ”SCALE MODIFICAT.”
You can call up further screen forms with input
fields for other R parameters with the page
up/down keys ...
or
... you can call up an input screen form or a particular
R parameter using the alphanumeric keys and the
search key (”33” in example, ”R” need not be
entered).
Enter the value for the selected R parameter with the
numerical keys.
Subsequently, you can transfer the value into the
input field with the input key.
”SPINDLE” setting data
Using an input screen form, you can enter/modify the following spindle data via
”SETTING DATA”:
or
3
L
3
L
...
...
• • •
Designation
Standard
setting data
(delivery
state)
Maximum
input
value
1)
Input
unit
2)
Smoothing constant with threading
Progammed spindle speed limitation
Oriented spindle stop
Spindle speed limitation (absolute)
0
0
0
0
5
16000
359.9
16000
-
rev / min
1 / 10 degree
rev / min
1) The ”Maximum input value” is fixed in MD.
2) The ”Input unit” is fixed in MD:
you can also use 0.1 rev/min instead of rev/min.
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
3-27
SINUMERIK 810T, GA3 (BN)