4 Monitoring Functions

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

3007

”Wrong setting data program”

Reason:

Remedy:

– G25/G26 has been programmed
– G92 has been programmed with an address other than ”S” or ”P”
– M19 has been programmed with an address other than ”S”
As for alarm 3000

Alarm No.

Alarm Text:

3008

”Subroutine error”

Reason:

Remedy:

– Subroutine call without pass count ”P”
– M30 has been programmed as end of program
– M17 missing at end of program
– 5 levels of nesting have been called
– M17 has been programmed in a main program
As for alarm 3000

Alarm No.

Alarm Text:

3009

”Program disabled”

Explanation:

– L0 preselected in the AUTOMATIC display (not permitted).
– Missing program called by PLC.

Alarm No.

Alarm Text:

3010

”Intersection error”

Reason:

Remedy:

This error can appear in conjunction with the L95 stock removal cycle,
when:
– A contouring program has been programmed without G00, G01,

G02, G03

– @ 714 has been programmed in a contouring program
– An incorrect plane has been selected in a contouring program
– No intersection point has been found
– More than a quarter circle has been programmed in a contouring

program

As for alarm 3000

Alarm No.

Alarm Text:

3011

”Too many axes/axes twice”

Reason:

Remedy:

– An axis has been programmed twice in the same block
– More axes have been programmed than present on the machine
As for alarm 3000